ASAP2800_15 Datasheet, PDF (5/8 Pages) International Rectifier – HIGH RELIABILITY HYBRID DC-DC CONVERTERS
ASAP Series
Notes to Specifications for Table on page 4
1. Parameter guaranteed by line, load, and cross regulation tests.
2. Up to 80%of full power is available from either output provided the total output does not exceed 6.0 W.
3. Bandwidth of DC to 20 MHz is guaranteed by design. Tested for 20 KHz to 2.0 MHz.
4. Load current split equally between +V and -V .
OUT
OUT
5. 1.2 watt load on output under test, 1.2 to 4.8 watt load change on other output.
6. Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in
excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
7. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall
be guaranteed to the limits specified.
8. An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is
the condition of maximum power dissipation.
9. Load step transition time between 2.0 and 10 microseconds.
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0 percent of VOUT at 50%
load.
11. Input step transition time between 2.0 and 10 microseconds.
12. Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from
enable pin (pin 5) with power applied to the input.
www.irf.com
5