English
Language : 

IRAM136-0760A2 Datasheet, PDF (4/17 Pages) International Rectifier – 5A, 600V with Open Emitter Pins
IRAM136-0760A
Inverter Section Switching Characteristics @ TJ= 25°C
Symbol
Parameter
Min Typ Max Units Conditions
EON
Turn-On Switching Loss
--- 210 340
IC=3.5A, V+=400V
EOFF
Turn-Off Switching Loss
ETOT
Total Switching Loss
---
20
30
VCC=15V, L=1.2mH
---
245 370
μJ Energy losses include "tail" and
diode reverse recovery
EREC
Diode Reverse Recovery energy
---
15
25
tRR
Diode Reverse Recovery time
--- 135 ---
ns
See CT1
EON
Turn-on Switching Loss
--- 300 ---
IC=3.5A, V+=400V
EOFF
Turn-off Switching Loss
ETOT
Total Switching Loss
---
50
---
--- 350 ---
VCC=15V, L=1.2mH, TJ=150°C
μJ Energy losses include "tail" and
diode reverse recovery
EREC
Diode Reverse Recovery energy
---
30
---
tRR
Diode Reverse Recovery time
--- 170 ---
ns
See CT1
QG
Turn-On IGBT Gate Charge
---
9
13
nC IC=4A, V+=400V, VCC=15V
RBSOA
SCSOA
Reverse Bias Safe Operating Area
FULL SQUARE
Short Circuit Safe Operating Area 5
---
---
TJ=150°C, IC=3.5A, VP=600V
V+= 450V
VCC=+15V to 0V
See CT3
TJ=25°C, VP=600V,
μs V+= 360V,
VCC=+15V to 0V
See CT2
ICSC
Short Circuit Collector Current
---
30
---
A TJ=25°C, V+= 400V, VCC=15V
See CT2
Recommended Operating Conditions Driver Function
The Input/Output logic timing diagram is shown in Figure 1. For proper operation the device should be used within the
recommended conditions. All voltages are absolute referenced to COM. The VS offset is tested with all supplies biased at
15V differential (Note 3)
Symbol
Definition
Min
Typ
Max
VB1,2,3
VS1,2,3
High side floating supply voltage
High side floating supply offset voltage
VS+12
Note 4
VS+15
---
VS+20
450
VCC
VITRIP
Low side and logic fixed supply voltage
ITRIP input voltage
12
15
20
VSS
---
VSS+5
VIN
Logic input voltage LIN, HIN, FLT/EN
VSS
---
VSS+5
HIN
High side PWM pulse width
1
---
---
Deadtime
External dead time between HIN and LIN
1
---
---
Note 3: For more details, see IR21364 data sheet
Note 4: Logic operational for Vs from COM-5V to COM+600V. Logic state held for Vs from COM-5V to COM-VBS.
(please refer to DT97-3 for more details)
Units
V
V
V
μs
μs
4
www.irf.com