English
Language : 

AMF2812D Datasheet, PDF (4/8 Pages) International Rectifier – HYBRID-HIGH RELIABILITY RADIATION TOLERANT DC-DC CONVERTER
AMF28XXD SERIES
(28V Input, Dual Output)
Dynamic Characteristics -55°C ≤ TCASE ≤ +125°C, VIN = 28VDC ± 5%, CL = 0, unless otherwise specified.
Parameter
Group A
Subgroups
Test Conditions
Min Nom Max Unit
Short Circuit Recovery 6
AMF2805D
AMF2812D
AMF2815D
4, 5, 6
0% load to 100% load
25
25
ms
25
Switching Frequency 3
Synchronization Input 3
Frequency Range
Pulse Amplitude, Hi 6
Pulse Amplitude, Lo 6
Pulse Rise Time 6
Pulse Duty Cycle 6
4, 5, 6
4, 5, 6
100% load
500 550 600 kHz
500
700 kHz
2.5
10
V
-0.5
0.8
V
100
ns
20
80
%
Output Response To Step Transient
Load Changes 3, 7
Recovery Time, Step Transient Load
Changes 3, 7, 8
Output Response Transient Step
Line Changes 3, 6, 9
AMF2805D
AMF2812D
AMF2815D
Recovery Time Transient Step Line
Changes 3, 6, 9
Turn On Overshoot 3, 10
All
AMF2805D
AMF2812D
AMF2815D
Turn On Delay 3, 10
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
Load step 50%100%
Load step 0% 50%
Load step 50%100%
Load step 0%  50%
-200
-800
Input step 16  40VDC,
100% load
Input step 16  40VDC,
100% load
0% load
100% load
-450
-750
-750
0% load to 100% load
+200
+800
70
2000
mVpk
s
+450
+750
+750
mVpk
1200 s
600
400 mVpk
300
300
25
ms
Notes to Specifications
1. Applicable to positive and negative outputs..
2. Maximum combined output is 12 watts. 10.8 watts (max.) is available from either output (90%).
3. Load current split equally between +VOUT and –VOUT.
4. 1.2 watt load on output under test, 1.2 watt to 10.8 watt load change on other output.
5. Capacitive value may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in
excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
6. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be
guaranteed to the limit specified.
7. Load step transition time between 2.0µs and 10µs.
8. Recovery time is measured from initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
9. Input step transient time between 1.0µs and 10µs.
10 Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin while power is applied to the input.
4
2016-06-22