Dynamic Characteristics -55°C ≤ TCASE ≤ +125°C, VIN = 28VDC ± 5%, CL = 0, unless otherwise specified.
Parameter
Group A
Subgroups
Test Conditions
Min Nom Max Unit
Synchronization Input
Frequency Range
Pulse Amplitude, Hi 4
Pulse Amplitude, Lo 4
Pulse Rise time 4
Pulse Duty Cycle 4
Output Response to Step Transient
Load Changes 5
All Models
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
500
2.5
-0.5
20
Load step 50%  100%
Load step 0%  50%
-300
-400
-500
-750
-750
-750
700 kHz
10
V
0.8
V
100
ns
80
%
+300
+400
+500
+750
+750
+750
mVpk
Recovery Time, Step Transient
Load Changes 5, 6
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
Load step 50% 100%
70
70
100
µs
100
100
All Models
Output Response Transient Step
Line Changes 4, 7
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
Recovery Time Transient Step Line
Changes 4, 7
Turn On Overshoot 8
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
Turn On Delay 8
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
Load step 0%  50%
Input step 16  40VDC,
100% Load
Input step 16  40VDC,
100% load
-500
-500
-1200
-1500
-1500
0% load to 100% load
0% load to 100% load
2.0
ms
+500
+500
+1200
+1500
+1500
mVpk
800 ms
400
600
600 mVpk
600
750
20
ms
Notes to Specifications
1. Parameter guaranteed by line and load regulation tests.
2. Bandwidth guaranteed by design. Tested for 20 Hz to 2.0MHz.
3. Capacitive value may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in
excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
4. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be
guaranteed to the limit specified.
5. Load step transition time between 2 and 10 microseconds.
6. Recovery time is measured from initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
7. Input step transient time between 1 and 10 microseconds.
8. Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the