English
Language : 

80CNQ Datasheet, PDF (4/6 Pages) International Rectifier – SCHOTTKY RECTIFIER
80CNQ... Series
PD-2.216 rev. C 01/99
160
140
DC
120
Square wave (D = 0.50)
80% Rated VR applied
100
see note (2)
80
0 10 20 30 40 50 60
Average Forward Current - I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current (Per Leg)
10000
30
D = 0.20
D = 0.25
25 D = 0.33
D = 0.50
20 D = 0.75
RMS Limit
15
DC
10
5
0
0 10 20 30 40 50 60
Average Forward Current - I F(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
(Per Leg)
DUT
C URRE NT
MONITOR
1000
At Any Rated Load Condition
And With
Following
Rated
Surge
V
RRM
Applied
100
10
100
1000
10000
Square Wave Pulse Duration - t p (microsec)
Fig. 7 - Max. Non-Repetitive Surge Current (Per Leg)
L
IRFP460
Rg = 25 ohm
HIGH-SPEED
SWITCH
FREE-WHEEL
DIODE
40HFL40S02
+ Vd = 25 Volt
Fig. 8 - Unclamped Inductive Test Circuit
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = I x V @ (I / D) (see Fig. 6);
F(AV) FM
F(AV)
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1= 80% rated VR
4
www.irf.com