English
Language : 

70CRU02 Datasheet, PDF (4/6 Pages) International Rectifier – Ultrafast Rectifier
70CRU02
Bulletin PD-20619 rev. B 02/02
180
170
160
150
DC
140
130
120 Square wave (D = 0.50)
110 Rated Vr applied
100
90 see note (3)
80
0 10 20 30 40 50 60
Average Forward Current - I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
80
If = 35A
70 Vrr = 100V
60
50
Tj = 125˚C
40
30
Tj = 25˚C
20
10
0
100
1000
di F /dt (A/µs )
Fig. 7 - Typical Reverse Recovery vs. di F /dt
50
40
30
RMS Limit
20
10
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
DC
0
0 10 20 30 40 50 60
Average Forward Current - I F(AV)(A)
Fig. 6 - Forward Power Loss Characteristics
600
If = 35A
Vrr = 100V
500
400
Tj = 125˚C
300
200
Tj = 25˚C
100
0
100
1000
di F /dt (A/µs )
Fig. 8 - Typical Stored Charge vs. di F /dt
(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR
4
www.irf.com