English
Language : 

403CMQ Datasheet, PDF (4/5 Pages) International Rectifier – SCHOTTKY RECTIFIER
403CMQ... Series
Bulletin PD-20726 rev. B 08/01
200
160
DC
120
80
Square wave (D = 0.50)
Rated VRapplied
40
see note (2)
0
0
100
200
300
AverageForwardCurrent-I F(AV)(A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
100000
200
D = 0.20
D = 0.25
D = 0.33
150 D = 0.50
D = 0.75
RMS Limit
DC
100
50
0
0 50 100 150 200 250 300
Average Forward Current - I F(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
10000
At Any Rated Load Condition
And With Rated VRRM Applied
Following Surge
DUT
CURRENT
M O N ITO R
1000
10
100
1000
10000
SquareWavePulseDuration-t p(microsec)
Fig. 7 - Max. Non-Repetitive Surge Current
L
IRFP460
Rg = 25 ohm
HIG H-SPEED
SW ITC H
FREE-W HE EL
D IO D E
40H FL40S02
+ Vd = 25 Volt
Fig. 8 - Unclamped Inductive Test Circuit
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR
4