English
Language : 

401CNQ045 Datasheet, PDF (4/5 Pages) International Rectifier – SCHOTTKY RECTIFIER
401CNQ... Series
Bulletin PD-2.263 rev. D 07/01
180
175
160
140
DC
120
100
Square wave (D = 0.50)
80 80% Rated VRapplied
60
see note (2)
40
0
100
200
300
Average Forward Current - I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
100000
150
125 D = 0.20
D = 0.25
100 D = 0.33
D = 0.50
75 D = 0.75
50
RMS Limit
DC
25
0
0 50 100 150 200 250 300
Average Forward Current - I F(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
At Any Rated Load Condition
And With Rated VRRM Applied
Following Surge
10000
DUT
C URRE NT
M ONITOR
1000
10
100
1000
10000
SquareWavePulseDuration-t p(microsec)
Fig. 7 - Max. Non-Repetitive Surge Current
L
IR F P 46 0
Rg = 25 ohm
HIG H-SPEED
SW ITC H
FR EE-W HEEL
D IO D E
4 0H FL40 S02
+ Vd = 25 Volt
Fig. 8 - Unclamped Inductive Test Circuit
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR
4