English
Language : 

400CMQ035 Datasheet, PDF (4/5 Pages) International Rectifier – SCHOTTKY RECTIFIER
400CMQ... Series
Bulletin PD-20734 rev. B 08/01
180
150
DC
120
90
60 Square wave (D = 0.50)
80% Rated VRapplied
30
see note (2)
0
0
100
200
300
Average Forward Current - I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
100000
180
150
D = 0.20
D = 0.25
120 D = 0.33
D = 0.50
90 D = 0.75
60
RMS Limit
DC
30
0
0 50 100 150 200 250 300
Average Forward Current - I F(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
At Any Rated Load Condition
And With Rated VRRM Applied
Following Surge
10000
DUT
CURRENT
M O N ITO R
1000
10
100
1000
10000
Square Wave Pulse Duration - t p (microsec)
Fig. 7 - Max. Non-Repetitive Surge Current
L
IRFP460
Rg = 25 ohm
HIG H-SPEED
SW ITC H
FREE-W HE EL
D IO D E
40H FL40S02
Fig. 8 - Unclamped Inductive Test Circuit
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR
4
+ Vd = 25 Volt
www.irf.com