English
Language : 

20CTH03SPBF Datasheet, PDF (4/9 Pages) International Rectifier – Hyperfast Rectifier
20CTH03SPbF, 20CTH03-1PbF
Bulletin PD-21070 07/05
180
170
DC
160
Square wave (D = 0.50)
150 Rated Vr applied
see note (2)
140
0 2 4 6 8 10 12 14 16
Average Forward Current - I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
20
16
RMS Limit
12
8
D = 0.01
D = 0.02
D = 0.05
4
D = 0.1
DC
D = 0.2
D = 0.5
0
0 2 4 6 8 10 12 14 16
Average Forward Current - IF(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
100
IF = 10A
Tj = 125˚C
Tj = 25˚C
Vr = 200V
10
100
1000
di F /dt (A/µs )
Fig. 7 - Typical Reverse Recovery vs. di F /dt
1000
IF = 10A
Tj = 125˚C
100
Tj = 25˚C
Vr = 200V
10
100
1000
di F /dt (A/µs )
Fig. 8 - Typical Stored Charge vs. di F /dt
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 8);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR
4
www.irf.com