Parameter Temperature Trends
Figures 42-117 provide information on the experimental performance of the IRS26302DJ HVIC. The line
plotted in each figure is generated from actual lab data. A large number of individual samples were tested at
three temperatures (-40 ºC, 25 ºC, and 125 ºC) in order to generate the experimental (Exp.) curve. The line
labeled Exp. consist of three data points (one data point at each of the tested temperatures) that have been
connected together to illustrate the understood trend. The individual data points on the curve were
determined by calculating the averaged experimental value of the parameter (for a given temperature).
10.5
8.4
6.3
4.2
Exp.
2.1
0.0
-50 -25
0 25 50 75
Temperature (oC)
100 125
Fig. 42. Offset Supply Leakage Current vs.
Temperature
1500.00
1200.00
900.00
600.00 Exp
.
300.00
0.00
-50 -25
0 25 50 75
Temperature (oC)
100 125
Fig. 44. Input Bias Current vs. Temperature
0.35
0.30
0.25
0.20
0.15
0.10
Exp .
0.05
0.00
-50 -25
0 25 50 75 100 125
Temperature (oC)
Fig. 43. Input Bias Current vs. Temperature
0.05
0.04
0.03
0.02
Exp.
0.01
0.00
-0.01
-50 -25
0 25 50 75 100 125
Temperature (oC)
Fig. 45. RCIN Input Bias Current vs.
Temperature
www.irf.com
© 2009 International Rectifier
36