English
Language : 

ATR2812T Datasheet, PDF (3/6 Pages) International Rectifier – ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
ATR28XXT Series
Specifications
TCASE = -55°C to +125°C, VIN = +28V ± 5% unless otherwise specified
ABSOLUTE MAXIMUM RATINGS
Input Voltage
-0.5V to 50VDC
Power Output
Internally limited, 37.5W typical
Soldering
Temperature Range6
300°C for 10 seconds
Operating
-55°C to +135°C case
Storage
-65°C to +135°C
Conditions
-55°C ≤ TC ≤ +125°C,
Test
Symbol
VIN = 28 VDC ±5%, CL=0,
unless otherwise specified
STATIC CHARACTERISTICS
Output Response to
Transient step9
Line changes10
Recovery Time8
Transient step9
Line changes10
Turn on Overshoot1
Turn on Delay 1, 11
Load Fault Recovery10
Device weight
VOTLINE
TTLINE
VTonOS
TonD
TRLF
Input step 16 from/to 40 VDC
IOUT = 4000mA (main)
POUT = 10W (dual)
Input step 16 from/to 40 VDC
IOUT = 4000mA (main)
POUT = 10W (dual)
IOUT = 0, and 4000mA (main)
POUT = 0, 10W (dual)
IOUT = 0, 4000mA (main)
POUT = 0, 10W (dual)
ATR2812T
ATR2815T
Min
Max
Min
Max Units
±1500
±1500 mV pk
10
1000
25
25
65
10
1000
25
25
65
ms
mV pk
ms
ms
g
Notes to Specifications
1. Tested at each output.
2. Parameter guaranteed byline and load regulation tests.
3. Although operation with no load is permissible, light loading on the main (+5 volt) output may cause the output voltage of the
auxiliary outputs (±12 volt or ±15 volt) to drop out of regulation. It is therefore recommended that at least 100mA or 20 percent of
the output power, whichever is greater, be taken from the main (+5 volt) output.
4. Total combined output power –30 watts.
5. Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
6. An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the overload protection
circuit and is the condition of maximum power dissipation.
7. Load step transition time between 2 and 10 microseconds.
8. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50 percent
load.
9. Input step transition time between 2 to 10 microseconds.
10. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified in the table.
11. Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 8) while power is applied to the input.
www.irf.com
3