English
Language : 

70TPS12 Datasheet, PDF (3/7 Pages) International Rectifier – PHASE CONTROL SCR
70TPS.. SAFEIR Series
Bulletin I2164 Rev. A 10/04
Triggering
Parameters
PGM Max. peak Gate Power
PG(AV) Max. average Gate Power
IGM Max. peak Gate Current
- VGM Max. peak negative Gate Voltage
VGT Max. required DC Gate Voltage
to trigger
IGT Max. required DC Gate Current
to trigger
VGD Max. DC Gate Voltage not to trigger
IGD Max. DC Gate Current not to trigger
70TPS..
10
2.5
2.5
10
4.0
1.5
1.1
270
100
80
0.25
6
Units
W
A
V
mA
V
mA
t = 30µs
Conditions
TJ = - 40°C
Anode supply = 6V
TJ = 25°C
resistive load
TJ = 125°C
TJ = - 40°C
TJ = 25°C
TJ = 125°C
TJ = 125°C, VDRM = rated value
Thermal-Mechanical Specifications
Parameters
70TPS.. Units
TJ Max. Junction Temperature Range
Tstg Max. Storage Temperature Range
RthJC Max. Thermal Resistance Junction
to Case
- 40 to 125
- 40 to 150
0.27
°C
°C/W
RthJA Max. Thermal Resistance Junction
40
to Ambient
RthCS Max. Thermal Resistance Case
0.2
to Heatsink
wt Approximate Weight
6 (0.21) g (oz.)
T Mounting Torque
Min.
6 (5) Kg-cm
Max.
12 (10) (lbf-in)
Case Style
Super-247
Conditions
DC operation
Mounting surface, smooth and greased
∆R Conduction (per Junction)
(The following table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC)
Device
180o
Sine half wave conduction
120o
90o
60o
30o
Rect. wave conduction
180o 120o
90o
60o
30o
70TPS 0.078 0.092 0.117 0.172 0.302 0.053 0.092 0.125 0.180 0.306
Units
°C/W
www.irf.com
3