60EPF06 Datasheet, PDF (3/8 Pages) International Rectifier – FAST SOFT RECOVERY RECTIFIER DIODE
60EPF.. 60CPF.. QUIETIR Series
Bulletin I2113 rev. D 04/99
Thermal-Mechanical Specifications
Parameters
TJ Max.JunctionTemperatureRange
Tstg Max.StorageTemperatureRange
RthJC Max.ThermalResistanceJunction
to Case
RthJA Max.ThermalResistanceJunction
to Ambient
RthCS TypicalThermalResistance,Caseto
Heatsink
wt ApproximateWeight
T MountingTorque
Min.
Max.
Case Style
60.PF.. Units
-40to150 °C
-40to150 °C
0.4
°C/W
40
°C/W
0.2
°C/W
6(0.21) g(oz.)
6(5) Kg-cm
12(10) (Ibf-in)
TO-247AC
Conditions
DC operation
Mounting surface , smooth and greased
JEDEC (Modified)
150
60.PF.. Series
140
R thJC (DC) = 0.4 K/W
130
Conduction Angle
120
110
100
90
0
90°
60°
30°
120°
180°
10 20 30 40 50 60 70
Average Forward Current (A)
Fig. 1 - Current Rating Characteristics
90
180°
80
120°
90°
70
60°
30°
60
RMS Limit
50
40
30
Conduction Angle
20
60.PF.. Series
10
TJ = 150°C
0
0 10 20 30 40 50 60 70
Average Forward Current (A)
Fig. 3 - Forward Power Loss Characteristics
www.irf.com
150
60.PF.. Series
140
R thJC (DC) = 0.4 K/W
130
Conduction Period
120
110
100
90
0
60°
30° 90°
120°
180° DC
20
40
60
80 100
Average Forward Current (A)
Fig. 2 - Current Rating Characteristics
140
DC
120
180°
120°
90°
100
60°
30°
80
60 RMS Limit
40
Conduction Period
20
60.PF.. Series
T J = 150°C
0
0
20
40
60
80 100
Average Forward Current (A)
Fig. 4 - Forward Power Loss Characteristics
3