English
Language : 

IRMCK171 Datasheet, PDF (24/34 Pages) International Rectifier – High Performance Sensorless Motor Control IC
IRMCK171
6.10 UART AC Timing
TBAUD
TXD
Start Bit
Data and Parity Bit
Stop Bit
RXD
TUARTFIL
Figure 13 UART timing
Unless specified, Ta = 25˚C.
Symbol
Parameter
TBAUD
TUARTFIL
Baud Rate Period
UART sampling filter
period (1)
Min
Typ
-
57600
-
1/16
Table 19 UART AC Timing
Max
-
-
Unit
bit/sec
TBAUD
Note:
(1) Each bit including start and stop bit is sampled three times at center of a bit at an interval of 1/16
TBAUD. If three sampled values do not agree, then UART noise error is generated.
This document is the property of International Rectifier and may not be copied or distributed without expressed consent.