English
Language : 

UFB120FA40 Datasheet, PDF (2/6 Pages) International Rectifier – Insulated Ultrafast Rectifier Module
UFB120FA40
Bulletin PD-20488 12/01
Electrical Characteristics @ TJ = 25°C (unless otherwise specified) per diode
Parameters
Min Typ Max Units Test Conditions
VBR
Cathode Anode
Breakdown Voltage
400 -
-
V IR = 100µA
VFM
Forward Voltage
IRM
Reverse Leakage Current
- 1.16 1.37 V IF = 60A
- 0.96 1.13 V IF = 60A, TJ = 150°C
-
- 0.1 mA VR = VR Rated
-
-
1 mA TJ = 150°C, VR = VR Rated
CT
Junction Capacitance
- 67 - pF VR = 400V
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) per diode
Parameters
Min Typ Max Units Test Conditions
trr
Reverse Recovery Time
IRRM
Peak Recovery Current
Qrr
Reverse Recovery Charge
- 30 35
- 65 -
- 128 -
- 7.4 -
- 17.8 -
- 240 -
- 1139 -
ns IF = 1.0A, diF/dt = 200A/µs, VR = 30V
TJ = 25°C
TJ = 125°C
A TJ = 25°C
IF = 50A
VR = 200V
diF /dt = 200A/µs
TJ = 125°C
nC TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Parameters
RthJC
RthCS
Wt
T
Junction to Case
Single Diode Conducting
Both Diodes Conducting
Case to Heat Sink, Flat, Greased Surface
Weight
Mounting Torque
Min Typ Max
-
0.99 1.24
-
0.49 0.62
-
0.05
-
-
30
-
-
1.3
-
Units
°C/W
°C/W
g
(N*m)
2
www.irf.com