English
Language : 

OM186STM Datasheet, PDF (2/5 Pages) International Rectifier – Adjustable Low Dropout Positive Voltage Regulator
OM186ST
Electrical Characteristics ÃTJ = 25°C (Unless Otherwise Specified)
Parameter
Reference Voltage
Line Regulation
Load Regulation
Dropout Voltage
Current Limit
Test Conditions
IOUT = 10mA, (VIN - VOUT) = 3.0V
e 10mA ≤ IOUT ≤ IFULL LOAD, 1.5V ≤ (VIN - VOUT) ≤ 25V
ILOAD = 10mA, 1.5V d (VIN - VOUT) dÃ15V
cd
(VIN - VOUT) = 3.0V, 10mA dÃIOUTÃdÃIFULL LOAD
cde
U f VREF = 1%, IOUT = IFULL LOAD
(VIN - VOUT) = 5.0V
(VIN - VOUT) = 25V
Min.
1.238
1.220
-
-
-
-
-
1.5
0.075
Typ.
1.250
1.250
0.015
0.035
0.5
0.8
1.3
-
-
Minimum Load Current (VIN - VOUT) = 25V
-
5.0
Max.
1.262
1.270
0.2
0.2
0.8
1.0
1.5
-
-
Units
V
%
V
A
10
mA
Thermal Regulation 30ms Pulse Width (Guaranteed by design)
-
0.010 0.05 %/W
Ripple Rejection
Adjust Pin Current
f = 120Hz, CAdj = 25€F Tantalum
IOUT - IFULL LOAD (VIN - VOUT) = 3.0V
Adjust Pin Current
Change
Temperature Stability
Long Term Stability
10mA ≤ IOUT ≤ IFULL LOAD
1.5V ≤ (VIN - VOUT) ≤ 25V
-55°C ≤ TJ ≤ +125°C
TJ = 125°C, t = 1000hrs
60
75
-
dB
-
55
120
µA
-
0.2
5.0
-
0.5
-
%
-
0.3
1.0
Notes
1. Load and line regulation are measured at a constant junction temperature by low duty cycle pulse testing.
2. Line and load regulation are guaranteed up to the maximum power dissipation. Power dissipation is determined by
the input/output differential voltage and output current. Guaranteed maximum power dissipation will not be available
over the full input/output voltage range.
3. I FULL LOAD curve is defined as the minimum value of current limit as a function of input to output voltage.
Note that power dissipation is only achievable over a limited range of input to output voltage.
4. Dropout voltage is specified over the full output current range of the device.
2
www.irf.com