English
Language : 

IRF7701TR Datasheet, PDF (2/9 Pages) International Rectifier – Ultra Low On-Resistance
IRF7701
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
Min. Typ. Max. Units
Conditions
V(BR)DSS Drain-to-Source Breakdown Voltage
-12 ––– ––– V VGS = 0V, ID = -250µA
∆V(BR)DSS/∆TJ Breakdown Voltage Temp. Coefficient
RDS(on)
Static Drain-to-Source On-Resistance
––– -0.006 –––
––– ––– 0.011
––– ––– 0.015
––– ––– 0.022
V/°C
Ω
Reference to 25°C, ID = -1mA
VGS = -4.5V, ID = -10A ‚
VGS = -2.5V, ID = -8.5A ‚
VGS = -1.8V, ID = -7.0A ‚
VGS(th)
Gate Threshold Voltage
-0.45 ––– -1.2 V VDS = VGS, ID = -250µA
gfs
Forward Transconductance
21 ––– ––– S VDS = -10V, ID = -10A
IDSS
Drain-to-Source Leakage Current
––– ––– 1.0
––– ––– -25
µA
VDS = -12V, VGS = 0V
VDS = -9.6V, VGS = 0V, TJ = 70°C
IGSS
Gate-to-Source Forward Leakage
Gate-to-Source Reverse Leakage
––– ––– -100
VGS = -8.0V
––– ––– 100 nA VGS = 8.0V
Qg
Total Gate Charge
––– 69 100
ID = -8.0A
Qgs
Gate-to-Source Charge
Qgd
Gate-to-Drain ("Miller") Charge
––– 9.1 14
––– 21 32
nC VDS = -9.6V
VGS = -4.5V‚
td(on)
tr
td(off)
tf
Turn-On Delay Time
Rise Time
Turn-Off Delay Time
Fall Time
––– 19 ––– ns VDD = -6.0V
––– 20 –––
ID = -1.0A
––– 240 –––
RD = 6.0Ω
––– 220 –––
VGS = -4.5V‚
Ciss
Input Capacitance
––– 5050 –––
VGS = 0V
Coss
Output Capacitance
Crss
Reverse Transfer Capacitance
––– 1520 ––– pF VDS = -10V
––– 1120 –––
ƒ = 1.0MHz
Source-Drain Ratings and Characteristics
Parameter
IS
Continuous Source Current
(Body Diode)
ISM
Pulsed Source Current
(Body Diode) 
VSD
Diode Forward Voltage
trr
Reverse Recovery Time
Qrr
Reverse RecoveryCharge
Min.
–––
–––
–––
–––
–––
Typ.
–––
–––
–––
52
53
Max.
-1.5
-80
-1.2
78
80
Units
A
V
ns
nC
Conditions
MOSFET symbol
D
showing the
integral reverse
G
p-n junction diode.
S
TJ = 25°C, IS = -1.5A, VGS = 0V ‚
TJ = 25°C, IF = -1.5A
di/dt = 100A/µs ‚
Notes:
 Repetitive rating; pulse width limited by
max. junction temperature.
‚ Pulse width ≤ 300µs; duty cycle ≤ 2%.
ƒ When mounted on 1 inch square copper board, t<10 sec
2
www.irf.com