English
Language : 

HFB50HI20 Datasheet, PDF (2/5 Pages) International Rectifier – Ultrafast, Soft Recovery Diode
HFB50HI20
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
Min. Typ. Max. Units
Test Conditions
VBR
Cathode Anode Breakdown Voltage
200 — —
V IR = 100µA
VF
Forward Voltage
— — 1.34
IF = 50A, TJ = -55°C „
See Fig. 1 ƒ
—
— 1.28
V
IF = 50A, TJ = 25°C „
See Fig. 2
— — 1.7
IF = 100A, TJ = 25°C „
— — 1.69
IF = 100A, TJ = 125°C „
IR
Reverse Leakage Current
See Fig. 2 ƒ
— — 10 µA VR = VR Rated
— — 100 µA VR = VR Rated, TJ = 125°C
CT
Junction Capacitance, See Fig. 3
— — 330 pF VR = 200V
LS
Series Inductance
— 8.7 —
nH Measured from anode lead to cathode
lead, 6 mm ( 0.025 in ) from package
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Parameter
Min.
Reverse Recovery Time
—
Reverse Recovery Time
—
—
Peak Recovery Current
—
—
Reverse Recovery Charge
—
—
Peak Rate of Fall of Recovery Current —
During tb
—
Typ. Max. Units
Test Conditions
— 35 ns IF = 0.5A,VR = 30V, dif/dt = 300A/µs
42 — ns TJ = 25°C See Fig.
69 —
TJ = 125°C
5
IF = 50A
4.4 —
8.7 —
A TJ = 25°C See Fig.
A TJ = 125°C
6
VR = 160V
108 —
nC TJ = 25°C See Fig.
314 — nC TJ = 125°C
7 dif/dt = 200A/µs
390 — A/µs TJ = 25°C See Fig.
570 — A/µs TJ = 125°C
8
Thermal - Mechanical Characteristics
RthJC
Wt
Parameter
Junction-to-Case
Weight
Note:
ƒ Pulse Width < 300µs, Duty Cycle < 2%
„ Pins 2 and 3 externally tied together
2
Typ.
—
10.9
Max.
0.75
—
Units
°C/W
g
www.irf.com