English
Language : 

90SQ Datasheet, PDF (2/5 Pages) International Rectifier – SCHOTTKY RECTIFIER
90SQ... Series
Bulletin PD-2.222 rev. C 12/01
Voltage Ratings
Part number
VR Max. DC Reverse Voltage (V)
VRWM Max. Working Peak Reverse Voltage (V)
90SQ035
35
90SQ040
40
90SQ045
45
Absolute Maximum Ratings
Parameters
IF(AV) Max. Average Forward Current
* See Fig. 5
IFSM Max. Peak One Cycle Non-Repetitive
Surge Current * See Fig. 7
EAS Non-RepetitiveAvalancheEnergy
IAR RepetitiveAvalancheCurrent
90SQ
9
2150
340
12
1.8
Units
Conditions
A 50% duty cycle @ TC = 69° C, rectangular wave form
5µs Sine or 3µs Rect. pulse Following any rated
A
load condition and
10ms Sine or 6ms Rect. pulse with rated VRRM applied
mJ TJ = 25 °C, IAS= 1.8 Amps, L = 7.4 mH
A Current decaying linearly to zero in 1 µsec
Frequency limited by TJ max. VA = 1.5 x VR typical
Electrical Specifications
Parameters
VFM Max. Forward Voltage Drop (1)
* See Fig. 1
IRM Max. Reverse Leakage Current (1)
* See Fig. 2
CT Max. Junction Capacitance
LS Typical Series Inductance
dv/dt Max. Voltage Rate of Change
(Rated VR)
(1) Pulse Width < 300µs, Duty Cycle < 2%
90SQ
0.48
0.57
0.42
0.52
1.75
70
900
10.0
10000
Units
Conditions
V @ 9A
V @ 18A
TJ = 25 °C
V @ 9A
V @ 18A
TJ = 125 °C
mA TJ = 25 °C
mA TJ = 125 °C
VR = rated VR
pF VR = 5VDC, (test signal range 100Khz to 1Mhz) 25 °C
nH Measured lead to lead 5mm from body
V/ µs
Thermal-Mechanical Specifications
Parameters
TJ Max. Junction Temperature Range
Tstg Max. Storage Temperature Range
RthJL Max. Thermal Resistance Junction
to Lead
RthJA Typical Thermal Resistance,
Junction to Air
wt Approximate Weight
Case Style
90SQ Units
Conditions
-55 to 150 °C
-55 to 150 °C
8.0 °C/W DCoperation * See Fig. 4
1/8 inch lead leangth
44 °C/W
1.4(0.049) g (oz.)
DO - 204AR JEDEC
2
www.irf.com