English
Language : 

90CLQ100_15 Datasheet, PDF (2/4 Pages) International Rectifier – SCHOTTKY RECTIFIER
90CLQ100
Voltage Ratings
Part number
VR Max. DC Reverse Voltage (V) (Per Leg)
VRWM Max. Working Peak Reverse Voltage (V) (Per Leg)
90CLQ100
100
Absolute Maximum Ratings
Parameters
IF(AV) Max. Average Forward Current
See Fig. 5
IFSM Max. Peak One Cycle Non - Repetitive
Surge Current (Per Leg)
Limits
90
250
Units
Conditions
A 50% duty cycle @ TC = 69°C, square waveform
A @ tp = 8.3 ms half-sine
Electrical Specifications
Parameters
VFM Max. Forward Voltage Drop
(Per Leg) See Fig. 1Q
IRM Max. Reverse Leakage Current
(Per Leg) See Fig. 2Q
Limits
0.72
0.89
0.98
0.71
0.89
0.98
0.60
0.73
0.81
0.07
7.4
17
Units
V
V
V
V
V
V
V
V
V
mA
mA
mA
Conditions
@ 15A
@ 30A
@ 40A
TJ = -55°C R
@ 15A
@ 30A
@ 40A
TJ = 25°CR
@ 15A
@ 30A
@ 40A
TJ = 125°C R
TJ = 25°C
TJ = 100°C
TJ = 125°C
VR = rated VR R
CT Max. Junction Capacitance (Per Leg) 1000
L S Typical Series Inductance (Per Leg)
5.9
pF VR = 5VDC ( 1MHz, 25°C ) R
nH Measured from the center of anode pad to the center
of cathode pad
Thermal-Mechanical Specifications
Parameters
TJ Max.Junction Temperature Range
Tstg
RthJC
Max. Storage Temperature Range
Max. Thermal Resistance, Junction
to Case (Per Leg)
RthJC Max. Thermal Resistance, Junction
to Case (Per Package)
wt Weight (Typical)
Die Size (Typical)
Limits Units
-55 to 150 °C
-55 to 150 °C
1.25 °C/W
Conditions
DC operation See Fig. 4
0.63 °C/W DC operation
2.6
g
150X180 mils
Case Style
SMD-1
Q Pulse Width < 300µs, Duty Cycle < 2%
2
www.irf.com