English
Language : 

60LQ100 Datasheet, PDF (2/4 Pages) International Rectifier – SCHOTTKY RECTIFIER
60LQ100
Voltage Ratings
Part number
VR Max. DC Reverse Voltage (V)
VRWM Max. Working Peak Reverse Voltage (V)
60LQ100
100
Absolute Maximum Ratings
Parameters
60LQ100 Units
Conditions
IF(AV) Max. Average Forward Current
See Fig. 5
60
A
50% duty cycle @ TC = 102°C, rectangular waveform
‚
IFSM Max. Peak One Cycle Non - Repetitive 400
Surge Current
A
@ tp = 8.3 ms sine ‚
Electrical Specifications
Parameters
VFM Max. Forward Voltage Drop
See Fig. 1
IRM Max. Reverse Leakage Current
See Fig. 2
CT Max. Junction Capacitance
L S Typical Series Inductance
60LQ045
0.62
0.95
1.15
0.68
0.70
0.97
0.8
45
1400
2.8
Units
V
V
V
V
V
V
mA
mA
pF
nH
Conditions
@ 10A
@ 60A TJ = 25°C ‚
@ 120A
@ 10A
@ 60A
@ 120A
TJ = -55°C ‚
TJ = 125°C ‚
TJ = 25°C VR = rated VR ‚
TJ = 125°C
VR = 5VDC, ( 100KHz to 1MHz) 25°C ‚
Measured from center of bond pad to end of anode
bonding wire
Thermal-Mechanical Specifications
Parameters
TJ
Tstg
RthJC
Max.Junction Temperature Range
Max. Storage Temperature Range
Max. Thermal Resistance, Junction
to Case
RthJC Max. Thermal Resistance, Junction
to case
wt Weight (Typical)
Die Description (Square)
Case Style
60LQ100 Units
-55 to 150 °C
-55 to 150 °C
1.0 °C/W
Conditions
DC operation See Fig. 4
0.50 °C/W DC operation
2.6
g
0.20 inches
SMD-1
 Pulse Width < 300µs, Duty Cycle < 2%
‚ Pins 2 and 3 externally tied together
2
www.irf.com