English
Language : 

HFA210NJ60C Datasheet, PDF (1/5 Pages) International Rectifier – Ultrafast, Soft Recovery Diode
PD -2.448 rev. B 02/99
HEXFREDTM
Features
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of
Recovery Parameters
HFA210NJ60C
Ultrafast, Soft Recovery Diode
LUG
TERMINAL
ANODE 1
LUG
TERMINAL
ANODE 2
BASE COMMON CATHODE
VR = 600V
VF(typ.)ƒ = 1.2V
IF(AV) = 210A
Qrr (typ.) = 450nC
IRRM(typ.) = 10A
trr(typ.) = 35ns
di(rec)M/dt (typ.)ƒ = 240A/µs
Description
HEXFREDTMdiodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are ideally
suited for power converters, motors drives and other applications where
switching losses are significant portion of the total losses.
Absolute Maximum Ratings (per Leg)
Parameter
VR
IF @ TC = 25°C
IF @ TC = 100°C
IFSM
EAS
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Continuous Forward Current
Single Pulse Forward Current 
Non-Repetitive Avalanche Energy ‚
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max.
600
171
85
600
220
463
185
-55 to +150
TO-244AB
Units
V
A
µJ
W
C
Thermal - Mechanical Characteristics
Parameter
Min.
Typ.
Max. Units
RthJC
RthCS
Wt
Junction-to-Case, Single Leg Conducting
Junction-to-Case, Both Legs Conducting
Case-to-Sink, Flat, Greased Surface
Weight
––––
––––
––––
––––
––––
––––
0.10
79 (2.8)
0.27
0.135
––––
––––
°C/W
K/W
g (oz)
Mounting Torque „
Mounting Torque Center Hole
Terminal Torque
30 (3.4)
12 (1.4)
30 (3.4)
––––
––––
––––
40 (4.6)
18 (2.1)
40 (4.6)
lbf•in
(N•m)
Vertical Pull
2 inch Lever Pull
––––
––––
––––
––––
80
lbf•in
35
Note:  Limited by junction temperature
‚ L = 100µH, duty cycle limited by max TJ
ƒ 125°C
„ Mounting surface must be smooth, flat, free or burrs or other
protrusions. Apply a thin even film or thermal grease to mounting
surface. Gradually tighten each mounting bolt in 5-10 lbf•in steps
until desired or maximum torque limits are reached. Module
1