English
Language : 

HFA140MD60C Datasheet, PDF (1/5 Pages) International Rectifier – Ultrafast, Soft Recovery Diode
PD - 40009 rev. A 01/99
HEXFREDTM
Features
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of
Recovery Parameters
HFA140MD60C
Ultrafast, Soft Recovery Diode
LUG
LUG
LUG
TERMINAL TERMINAL TERMINAL
ANODE 1 CATHODE ANODE 2
Isolated Base
VR = 600V
VF(typ.)‚ = 1.2V
IF(AV) = 140A
Qrr (typ.) = 360nC
IRRM(typ.) = 8.0A
trr(typ.) = 35ns
di(rec)M/dt (typ.)‚ = 230A/µs
Description
HEXFREDTM diodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are ideally
suited for power converters, motors drives and other applications where
switching losses are significant portion of the total losses.
Absolute Maximum Ratings (per Leg)
VR
IF @ TC = 25°C
IF @ TC = 100°C
IFSM
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Parameter
Cathode to Anode Voltage
Continuous Forward Current
Continuous Forward Current
Single Pulse Forward Current 
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
TO-244AB
(ISOLATED)
Max.
600
99
48
600
227
91
55 to +150
Units
V
A
W
C
Thermal - Mechanical Characteristics
Parameter
Min.
Typ.
Max. Units
RthJC
RthCS
Junction to Case, Single Leg Conducting
Junction to Case, Both Legs Conducting
Case to Sink, Flat , Greased Surface
––––
––––
––––
––––
––––
0.10
0.55
0.275
––––
°C/W
K/W
Wt
Weight
––––
79 (2.8)
–––– g (oz)
Mounting Torque ƒ
Terminal Torque
30 (3.4)
30 (3.4)
––––
––––
40 (4.6) lbf•in
40 (4.6) (N•m)
Vertical Pull
2 inch Lever Pull
––––
––––
––––
––––
80
lbf•in
35
Note:  Limited by junction temperature
‚ 125°C
ƒ Mounting surface must be smooth, flat, free or burrs or other
protrusions. Apply a thin even film or thermal grease to mounting
surface. Gradually tighten each mounting bolt in 5-10 lbf•in steps
until desired or maximum torque limits are reached. Module
1