3. Technical Specifications
(All specifications are typical at nominal input, full load at 25℃ unless otherwise noted.)
PARAMETER
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Operating Temperature
Storage Temperature
Input/Output Isolation Voltage
NOTES and CONDITIONS
1 minute
Device
Min. Typical
Max.
90
264
0
+50
-20
+85
4242
INPUT CHARACTERISTICS
Operating Voltage Range
Input Frequency Range
Maximum Input Current
Leakage Current
Inrush Current
OUTPUT CHARACTERISTIC
100% Load, Vin=90Vac
Vin=264Vac, cold start at 250C.
Output Voltage Set Point
Vin=Nominal Vin , Io=Io.max, Tc=25℃
Operating Output Current Range
Holdup Time
Vin=115Vac
100
47
AC60S033
AC60S050
AC60S090
AC60S120
AC60S150
AC60S240
AC60S280
AC60S360
AC60S480
AC60S033
AC60S050
AC60S090
AC60S120
AC60S150
AC60S240
AC60S280
AC60S360
AC60S480
3.26
4.95
8.91
11.88
14.85
23.76
27.72
35.64
47.52
1.4
3.3
5.0
9.0
12.0
15.0
24.0
28.0
36.0
48.0
8
8
6.67
5
4
2.5
2
1.67
1.25
8
240
63
3.5
50
3.33
5.05
9.09
12.12
15.15
24.24
28.28
36.36
48.48
Output Voltage Regulation
Load Regulation
10% load to Full load
±1.0
Line Regulation
Vin=high line to low line
±0.5
Output Voltage Ripple and Noise 20MHz bandwidth
AC60S033
AC60S050
AC60S090
Peak-to-Peak
Full load, 0.1uF ceramic and
capacitor
10uF E.L
AC60S120
AC60S150
AC60S240
AC60S280
AC60S360
AC60S480
ISOLATION CHARACTERISTICS
Input to Output
1 minute
Input to Earth
1 minute
Output to Earth
1 minute
Isolation Resistance
100
50
50
90
120
150
240
280
360
480
4242
2121
707
FEATURE CHARACTERISTICS
Switching Frequency
60
GENERAL SPECIFICATIONS
MTBF
Weight
Io=100%of Io.max;Ta=25 ℃ per
MIL-HDBK-217F
TBD
0.175
Units
Vac
℃
℃
Vdc
Vac
Hz
A
mA
A
Vdc
A
mS
%
%
mV
Vdc
Vdc
Vdc
MΩ
KHz
M hours
Kg
Page 4