English
Language : 

X28HC64_09 Datasheet, PDF (9/17 Pages) Intersil Corporation – 5 Volt, Byte Alterable EEPROM
X28HC64
Absolute Maximum Ratings
Temperature Under Bias
X28HC64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-10°C to +85°C
X28HC64I. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on any Pin with Respect to Vss . . . . . . . . . . . . . . -1V to +7V
DC Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5mA
Thermal Information
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
*Pb-free PDIPs can be used for through hole wave solder
processing only. They are not intended for use in Reflow solder
processing applications.
Recommended Operating Conditions
Commercial Temperature Range. . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial Temperature Range . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage Range
X28HC64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
DC Electrical Specifications
Over recommended operating conditions, unless otherwise specified. Parameters with MIN and/or MAX
limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by
characterization and are not production tested.
PARAMETER
SYMBOL
TEST CONDITIONS
TYP
MIN (Note 3) MAX UNIT
VCC Current (active) (TTL Inputs)
ICC CE = OE = VIL, WE = VIH, All I/O’s = open, address
inputs = TTL levels @ f = 10 MHz
15
40 mA
VCC Current (Standby) (TTL Inputs)
ISB1 CE = VIH, OE = VIL All I/O’s = open, other inputs = VIH
VCC Current (Standby) (CMOS Inputs)
ISB2 CE = VCC - 0.3V, OE = GND, All I/O’s = open, other
inputs = VCC - 0.3V
Input Leakage Current
ILI
VIN = VSS to VCC
Output Leakage Current
ILO
VOUT = VSS to VCC, CE = VIH
Input LOW Voltage (Note 4)
VlL
Input HIGH Voltage (Note 4)
VIH
Output LOW Voltage
VOL IOL = 5mA
Output HIGH Voltage
VOH IOH = -5mA
NOTES:
3. Typical values are for TA = +25°C and nominal supply voltage
4. VIL min. and VIH max. are for reference only and are not tested.
1
2
mA
100
200 µA
±10 µA
±10 µA
-1
0.8
V
2
VCC + 1 V
0.4
V
2.4
V
Endurance and Data Retention
PARAMETER
Minimum Endurance
Data Retention
Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified.
Temperature limits established by characterization and are not production tested.
MIN
MAX
UNIT
100,000
Cycles
100
Years
9
FN8109.2
August 28, 2009