English
Language : 

HC-5504B1_03 Datasheet, PDF (9/10 Pages) Intersil Corporation – ITU Low Cost, PABX SLIC With 40mA Loop Feed
HC-5504B1
Applications Diagram
5V TO
12V
SYSTEM CONTROLLER
15
13
14
7 16
RS1 CS1
K1 POWER SWITCH GROUND RING RING
BALANCE NETWORK
DENIAL HOOK KEY SYNC CMD
8
DETECT DETECT
21
C5
TIP
RD
K1A
RB1
1
TIP
RB2 9
TIP FEED
(NOTE 5)
SLIC
HC-5504B1
RX
24
TX
20
+IN
19
C6
C7
R1
ZB
-IN
OP AMP
R3
SUBSCRIBER
LOOP
PRIMARY
PROTEC-
TION
K1B
VB -
10
RING FEED
RS2
3
RING FEED SENSE
R2
18
OUT
C2 17
5
CS2
RB4
2 NEG. BATT. DIG. ANA.
C3
22
C4
RING
PTC
RB3
RING BATT. GND. GND. GND. VB+
+
C4 C3 C2
11
12
6
23
4
C8
C9
+
PCM
FILTER/
CODEC
SWITCHING
NETWORK
Z1
-48V
-48V
150VPEAK (MAX)
RING GENERATOR
VB+
PIN NUMBERS GIVEN FOR DIP/SOIC PACKAGE.
FIGURE 1. TYPICAL LINE CIRCUIT APPLICATION WITH THE MONOLITHIC SLIC
Typical Component Values
C2 = 0.15µF, 10V.
C3 = 0.3µF, 30V.
C4 = 0.5µF to 1.0µF, 10%, 20V (Should be nonpolarized).
C5 = 0.5µF, 20V.
C6 = C7 = 0.5µF (10% Match Required) (Note 6).
C8 = 0.01µF, 100V.
R1 = R2 = R3 = 100kΩ (0.1% Match Required, 1% absolute
value) ZB = 0 for 600Ω Terminations (Note 6).
RB1 = RB2 = RB3 = RB4 = 150Ω (0.1% Match Required, 1%
absolute value).
RS1 = RS2 = 1kΩ, typically.
CS1 = CS2 = 0.1µF, 200V typically, depending on VRING
and line length.
C9 = 0.01µF, 20V, ±20%.
Z1 = 150V to 200V transient protection.
PTC used as ring generator ballast.
NOTES:
5. Secondary protection diode bridge recommended is a 2A, 200V type.
6. To obtain the specified transhybrid loss it is necessary for the three legs of the balance network, C6-R1 and R2 and C7-ZB-R3, to match in
impedance to within 0.3%. Thus, if C6 and C7 are 1µF each, a 20% match is adequate. It should be noted that the transmit output to C6 sees
a -22V step when the loop is closed. Too large a value for C6 may produce an excessively long transient at the op amp output to the PCM
Filter/CODEC.
7. A 0.5µF and 100kΩ gives a time constant of 50ms. The uncommitted op amp output is internally clamped to stay within ±6.6V and is current
limited.
8. All grounds (AG, BG, and DG) must be applied before VB+ or VB-. Failure to do so may result in premature failure of the part. If a user wishes
to run separate grounds off a line card, the AG must be applied first.
9. Application shows Ring Injected Ringing, Balanced or Tip injected configuration may be used.
9