English
Language : 

X9313 Datasheet, PDF (8/11 Pages) Xicor Inc. – E2POT™ Nonvolatile Digital Potentiometer
X9313
AC Operating Characteristics Over recommended operating conditions unless otherwise stated.
LIMITS
SYMBOL
PARAMETER
TYP
MIN
(Note 6)
tCI
CS to INC setup
tID
INC HIGH to U/D change
tDI
U/D to INC setup
tIL
INC LOW period
tIH
INC HIGH period
tIC
INC inactive to CS inactive
tCPH
CS deselect time (STORE)
tCPH
CS deselect time (NO STORE)
tIW
INC to VW change
tCYC
INC cycle time
tR, tF (Note 7) INC input rise and fall time
tPU (Note 7) Power-up to wiper stable
tR VCC (Note 7) VCC power-up rate
tWR
Store cycle
NOTES:
6. Typical values are for TA = 25°C and nominal supply voltage.
7. This parameter is not 100% tested.
100
100
2.9
1
1
1
20
100
1
4
0.2
5
MAX
5
500
5
50
10
UNIT
ns
ns
µs
µs
µs
µs
ms
ns
µs
µs
µs
µs
V/ms
ms
Power-Up and -Down Requirements
The recommended power-up sequence is to apply VCC/VSS
first, then the potentiometer voltages. During power-up, the
data sheet parameters for the DCP do not fully apply until 1
millisecond after VCC reaches its final value. The VCC ramp
AC Timing
spec is always in effect. In order to prevent unwanted tap
position changes, or an inadvertent store, bring the CS and
INC high before or concurrently with the VCC pin on power-
up.
CS
tCI
INC
U/D
tCYC
tIL
tIH
tIC
tID
tDI
tCPH
90% 90%
10%
tF
tR
tIW
VW
(SEE NOTE)
MI
NOTE:
MI IN THE AC TIMING DIAGRAM REFERS TO THE MINIMUM INCREMENTAL CHANGE IN THE VW OUTPUT DUE TO A CHANGE IN THE WIPER POSITION.
8
FN8177.2
September 9, 2005