English
Language : 

ISL23345 Datasheet, PDF (8/19 Pages) Intersil Corporation – Quad, 256 Tap, Low Voltage Digitally Controlled Potentiometer (XDCP™)
ISL23345
Serial Interface Specification for SCL, SDA, A0, A1, A2 Unless Otherwise Noted. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 20) (Note 8) (Note 20) UNITS
tDH
Output Data Hold Time
From SCL falling edge crossing 30% of VLOGIC,
0
until SDA enters the 30% to 70% of VLOGIC
window. IOL = 3mA, VLOGIC > 2V. IOL = 0.5mA,
VLOGIC < 2V
tR
SDA and SCL Rise Time
From 30% to 70% of VLOGIC
20 + 0.1 x Cb
tF
SDA and SCL Fall Time
From 70% to 30% of VLOGIC
20 + 0.1 x Cb
Cb
Capacitive Loading of SDA or SCL Total on-chip and off-chip
10
ns
250
ns
250
ns
400
pF
tSU:A
A1, A0, A2 Setup Time
Before START condition
600
ns
tHD:A
A1, A0, A2 Hold Time
After STOP condition
600
ns
NOTES:
8. Typical values are for TA = +25°C and 3.3V supply voltages.
9. LSB = [V(RW)255 – V(RW)0]/255. V(RW)255 and V(RW)0 are V(RW) for the DCP register set to FF hex and 00 hex respectively. LSB is the incremental
voltage when changing from one tap to an adjacent tap.
10. ZS error = V(RW)0/LSB.
11. FS error = [V(RW)255 – VCC]/LSB.
12. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 255. i is the DCP register setting.
13. INL = [V(RW)i – i • LSB – V(RW)0]/LSB for i = 1 to 255
14.
TCV
=
M------a----x---(--V---V-(--R-(--R--W--W---)--i-i-)-(--+-–---2-M--5---i-°-n---C-(---V)--)-(---R----W------)--i--)
×
------1----0----6-------
+ 165 °C
for i = 16 to 255 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
voltage and Min( ) is the minimum value of the wiper voltage over the temperature range.
15. MI = |RW255 – RW0|/255. MI is a minimum increment. RW255 and RW0 are the measured resistances for the DCP register set to FF hex and 00
hex respectively.
16. Roffset = RW0/MI, when measuring between RW and RL.
Roffset = RW255/MI, when measuring between RW and RH.
17. RDNL = (RWi – RWi-1)/MI -1, for i = 16 to 255.
18. RINL = [RWi – (MI • i) – RW0]/MI, for i = 16 to 255.
19.
TCR
=
-[--M-----a----x---(--R-----i--)---–-----M-----i--n----(--R----i--)---]
R i ( + 25 °C )
×
------1----0----6-------
+ 165 °C
for i = 16 to 255, T = -40°C to +125°C. Max( ) is the maximum value of the resistance and Min( ) is the
minimum value of the resistance over the temperature range.
20. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
21. It is preferable to ramp up both the VLOGIC and the VCC supplies at the same time. If this is not possible, it is recommended to ramp-up the VLOGIC
first followed by the VCC.
22. VMATCH = [V(RWx)i - V(RWy)i]/LSB, for i = 1 to 255, x = 0 to 3 and y = 0 to 3.
23. RMATCH = (RWi,x - RWi,y)/MI, for i = 1 to 255, x = 0 to 3 and y = 0 to 3.
8
FN7872.0
June 21, 2011