English
Language : 

ISL22343 Datasheet, PDF (8/18 Pages) Intersil Corporation – Quad Digitally Controlled Potentiometer XDCP
ISL22343
Operating Specifications Over the recommended operating conditions unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 21) (Note 5) (Note 21) UNIT
Cb
Capacitive Loading of SDA Total on-chip and off-chip
(Note 19) or SCL
10
400
pF
Rpu
SDA and SCL Bus Pull-up Maximum is determined by tR and tF
1
kΩ
(Note 19) Resistor Off-chip
For Cb = 400pF, max is about 2~2.5kΩ
For Cb = 40pF, max is about 15~20kΩ
tSU:A
A1 and A0 Setup Time
Before START condition
600
ns
tHD:A A1 and A0 Hold Time
After STOP condition
600
ns
NOTES:
5. Typical values are for TA = +25°C and 3.3V supply voltage.
6. LSB: [V(RW)255 – V(RW)0]/255. V(RW)255 and V(RW)0 are V(RW) for the DCP register set to FF hex and 00 hex respectively. LSB is the
incremental voltage when changing from one tap to an adjacent tap.
7. ZS error = V(RW)0/LSB.
8. FS error = [V(RW)255 – VCC]/LSB.
9. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 255. i is the DCP register setting.
10. INL = [V(RW)i – i • LSB – V(RW)0]/LSB for i = 1 to 255.
11. VMATCH= [V(RWx)i -V(RWy)i]/LSB, for i = 0 to 255, x = 0 to 3, y = 0 to 3.
12.
TCV
=
-------M-----a----x----(--V----(---R-----W------)--i--)---–-----M-----i--n----(--V-----(--R-----W------)--i--)------ × ----1---0----6----- for i = 16 to 240 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
[Max(V(RW)i) + Min(V(RW)i)] ⁄ 2 +165°C voltage and Min ( ) is the minimum value of the wiper voltage over the temperature range.
13. MI = |RW255 – RW0|/255. MI is a minimum increment. RW255 and RW0 are the measured resistances for the DCP register set to FF hex and
00 hex respectively.
14. Roffset = RW0/MI, when measuring between RW and RL.
Roffset = RW255/MI, when measuring between RW and RH.
15. RDNL = (RWi – RWi-1)/MI -1, for i = 16 to 255.
16. RINL = [RWi – (MI • i) – RW0]/MI, for i = 16 to 255.
17. RMATCH= [(Rx)i -(Ry)i]/MI, for i = 0 to 255, x = 0 to 3, y = 0 to 3.
18.
TCR
=
----[---M-----a----x----(--R-----i--)---–-----M-----i--n----(--R-----i--)--]---- × ----1----0---6-----
[Max(Ri) + Min(Ri)] ⁄ 2 +165°C
for i = 16 to 240, T = -40°C to +125°C. Max( ) is the maximum value of the resistance and
the minimum value of the resistance over the temperature range.
Min ( ) is
19. This parameter is not 100% tested.
20. tWC is the time from a valid STOP condition at the end of a Write sequence of I2C serial interface, to the end of the self-timed internal non-
volatile write cycle.
21. Parts are 100% tested at +25°C. Temperature limits established by characterization and are not production tested.
8