TABLE 8. BURN-IN AND IRRADIATION TEST CONNECTIONS
OSCILLATOR
FUNCTION
Static Burn-In 1
Note 1
OPEN
6, 7, 9, 10
GROUND
1-5, 8, 11-15
VDD
16
9V ± -0.5V
50kHz
25kHz
Static Burn-In 2
Note 1
6, 7, 9, 10
1, 8, 15
2-5, 11-14, 16
Dynamic Burn-
-
In Note 1
1, 4, 8, 12, 15
2, 14, 16
6, 7, 9, 10
5, 11
3, 13
Irradiation
Note 2
2, 6, 7, 9, 10, 14
1, 8, 15
3-5, 11-13, 16
NOTE:
1. Each pin except VDD and GND will have a series resistor of 10K ± 5%, VDD = 18V ± 0.5V
2. Each pin except VDD and GND will have a series resistor of 47K ± 5%; Group E, Subgroup 2, sample size is 4 dice/wafer, 0 failures, VDD
= 10V ± 0.5V
TABLE 9. FUNCTIONAL TERMINAL CONNECTIONS
VDD TO
TERM. NO.
VSS TO
TERM. NO.
INPUT PULSE TO
TERM. NO.
OTHER
CONNECTIONS
FUNCTION
MONO 1 MONO 2 MONO 1 MONO 2 MONO 1 MONO 2 MONO 1 MONO 2
Leading Edge Trigger/
Retriggerable
3, 5
11, 13
4
12
Leading Edge Trigger/
Non-Retriggerable
3
13
4
12
5-7
11-9
Trailing Edge Trigger/
Retriggerable
3
13
4
12
5
11
Trailing Edge Trigger/
Non-Retriggerable
3
13
5
11
4-6
12-10
Unused Section
5
11
3, 4
12, 13
NOTES:
1. A retriggerable one-shot multivibrator has an output pulse width which is extended one full time period (TX) after application of the last
trigger pulse. The minimum time between retriggering edges (or trigger and retrigger edges) is 40% of (TX).
2. A non-retriggerable one-shot multivibrator has a time period TX referenced from the application of the first trigger pulse.
INPUT PULSE TRAIN
RETRIGGERABLE MODE
PULSE WIDTH (+TR MODE)
NON-RETRIGGERABLE MODE
PULSE WIDTH (-TR MODE)
TX
TX
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate
and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which
may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site http://www.intersil.com
488