English
Language : 

X9C303 Datasheet, PDF (6/10 Pages) Xicor Inc. – Digitally Controlled Potentiometer (XDCP)
X9C303
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tIW
tCYC
tR, tF (4)
tPU (4)
tR VCC (4)
Parameter
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time
INC to VW change
INC cycle time
INC input rise and fall time
Power-up to wiper stable
VCC power-up rate
Min.
100
100
2.9
1
1
1
20
4
0.2
Limits
Typ. (3)
100
Max.
500
500
500
50
Unit
ns
ns
µs
µs
µs
µs
ms
µs
µs
ns
µs
mV/µs
A.C. TIMING
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
tCPH
90% 90%
10%
tF
tR
U/D
tIW
VW
MI (8)
Notes: (3) Typical values are for TA = 25°C and nominal supply voltage.
(4) This parameter is periodically sampled and not 100% tested.
(5) MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position.
6
FN8223.0
March 11, 2005