English
Language : 

X9511 Datasheet, PDF (6/9 Pages) Xicor Inc. – PushPot O Potentiometer (Push Button Controlled)
X9511
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Min.
0°C
-40°C
Max.
+70°C
+85°C
Supply Voltage
X9511
Limits
5V ± 10%
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
Parameter
Limits
Min. Typ.(4) Max. Unit
Test Conditions
ICC VCC active current
1
3
mA PU or PD held at VIL the other at VIH
ISB Standby supply current
100
200
µA PU = PD = VIH
ILI PU, PD, ASE input leakage current
10
µA VIN = VSS to VCC
VIH PU, PD, ASE input HIGH voltage
2
VCC + 1 V
VlL PU, PD, ASE input LOW voltage
-1
0.8
V
RW Wiper resistance
40
100
Ω Max. Wiper Current ±1mA
VVH VH terminal voltage
-5
+5
V
VVL VL terminal voltage
-5
CIN(5) ASE, PU, PD input capacitance
+5
V
10
pF VCC = 5V, VIN = 0V, TA = 25°C,
f = 1MHz
Notes: (4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
tGAP
tDB
tS SLOW
tS
(7)
FAST
tPU(7)
tR VCC(7)
tASTO(7)
VASTH(7)
VASEND(7)
Parameter
Time between two separate push button events
Debounce time
After debounce to wiper change on a slow mode
Wiper change on a fast mode
Power-up to wiper stable
VCC power-up rate
AUTOSTORE cycle time
AUTOSTORE threshold voltage
AUTOSTORE cycle end voltage
Min.
0
100
25
0.2
2
Limits
Typ.(6)
30
250
50
4
3.5
Max.
60
375
75
500
50
Unit
µs
ms
ms
ms
µs
mV/µs
ms
V
V
POWER-UPPOWER-DOWN AND DOWN REQUIREMENTS
The are no restrictions on the sequencing of VCC and the voltage applied to the potentiometer pins during power-up
or power-down conditions. During power-up, the data sheet parameters for the DCP do not fully apply until 1ms after
VCC reaches its final value. The VCC ramp rate spec is always in effect.
6
FN8205.1
September 6, 2005