English
Language : 

X9455_06 Datasheet, PDF (6/19 Pages) Intersil Corporation – Dual Two-wiper Digitally-Controlled Potentiometer
X9455
2-Wire Interface Timing (s) (Continued)
SYMBOL
PARAMETER
MIN
tSU:WPA A0, A1, A2 and WP Setup Time
600
(Note 5)
tHD:WPA
A0, A1, A2 and WP Hold Time
600
(Note 5)
SDA vs. SCL Timing
SCL
tSU:STA
SDA
(Input Timing)
SDA
(Output Timing)
tF
tHIGH
tSU:DAT
tHD:STA
tLOW
tR
tHD:DAT
tAA tDH
MAX
UNITS
ns
ns
tSU:STO
tBUF
WP, A0, A1, and A2 Pin Timing
START
SCL
Clk 1
SDA IN
WP, A0, A1, or A2
tSU:WP
STOP
tHD:WP
Increment/Decrement Timing
SYMBOL
PARAMETER
MIN
TYP (Note 4)
MAX
tCI
CS to SCL Setup
600
tID (Note 5) SCL HIGH to U/D, DS0 or DS1 change
600
tDI (Note 5) U/D, DS0 or DS1 to SCL setup
600
tIL
SCL LOW period
2.5
tIH
SCL HIGH period
2.5
tIC
SCL inactive to CS inactive (Nonvolatile Store Setup Time)
1
tCPHS
CS deselect time (STORE)
10
tCPHNS
CS deselect time (NO STORE)
1
(Note 5)
tIW (Note 5) SCL to RW change
tCYC
SCL cycle time
tR, tF (Note 5) SCL input rise and fall time
100
500
5
500
6
UNITS
ns
ns
ns
µs
µs
µs
ms
µs
µs
µs
µs
FN8202.1
July 28, 2006