English
Language : 

X9317 Datasheet, PDF (6/15 Pages) Intersil Corporation – Low Noise, Low Power, 100 Taps
X9317
Absolute Maximum Ratings
Junction Temperature Under Bias . . . . . . . . . . . . . .-65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D and VCC
with Respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
RH, RW, RL to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+6V
Lead Temperature (soldering 10s). . . . . . . . . . . . . . . . . . . . . . 300°C
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±8.8mA
CAUTION: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation
of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Potentiometer Specifications VCC = Full Range, TA = Full Operating Temperature Range unless otherwise stated
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
TYP
MIN (Note 4)
RTOTAL
VRH/RL
End to end resistance tolerance
RH/RL terminal voltage
Power rating
RW
Wiper resistance
IW
Wiper current (Note 5)
Noise (Note 7)
See ordering information for values
VSS = 0V
RTOTAL ≥ 10kΩ
RTOTAL = 1kΩ
IW = 1mA, VCC = 5V
IW = 1mA, VCC = 2.7V
See test circuit
Ref: 1kHz
-20
VSS
200
400
-4.4
-120
Resolution
1
Absolute linearity (Note 1)
V(RH) = VCC,
-1
V(RL) = 0V
Relative linearity (Note 2)
-0.2
MAX
+20
VCC
10
25
400
1000
+4.4
+1
+0.2
CH/CL/CW
(Note 5)
VCC
RTOTAL temperature coefficient (Note 5)
Ratiometric temperature coefficient
(Notes 5, 6)
Potentiometer capacitances
Supply Voltage
See equivalent circuit
X9317
X9317-2.7
±300
-20
+20
10/10/25
4.5
5.5
2.7
5.5
UNIT
%
V
mW
mW
Ω
Ω
mA
dBV
%
MI
(Note 3)
MI
(Note 3)
ppm/°C
ppm/°C
pF
V
V
DC Electrical Specifications VCC = 5V ±10%, TA = Full Operating Temperature Range unless otherwise stated
SYMBOL
PARAMETER
TEST CONDITIONS
TYP
MIN (Note 4)
MAX
ICC1
VCC active current (Increment)
ICC2
ISB
ILI
VIH
VCC active current (Store)
(non-volatile write)
Standby supply current
CS, INC, U/D input leakage current
CS, INC, U/D input HIGH voltage
CS = VIL, U/D = VIL or VIH and INC =
VIL/VIH @ min. tCYC
RL, RH, RW not connected
CS = VIH, U/D = VIL or VIH and INC = VIL
or VIH. RL, RH, RW not connected
CS ≥ VIH, U/D and INC = VIL
RL, RH, RW not connected
VIN = VSS to VCC
-10
VCC x
0.7
50
400
1
+10
VCC +
0.5
VIL
CS, INC, U/D input LOW voltage
-0.5
VCC x
0.1
UNIT
µA
µA
µA
µA
V
V
6
FN8183.1
September 9, 2005