English
Language : 

X9313ZSIZT1 Datasheet, PDF (6/12 Pages) Intersil Corporation – Linear, 32 Taps, 3 Wire Interface, Terminal Voltages VCC
X9313
DC Electrical Specifications Over recommended operating conditions, unless otherwise stated.
SYMBOL
ISB
PARAMETER
VCC Active Current
Standby Supply Current
ILI
VIH
VIL
CIN
(Note 5)
CS, INC, U/D Input Leakage Current
CS, INC, U/D Input HIGH Current
CS, INC, U/D Input LOW Current
CS, INC, U/D Input Capacitance
TEST CONDITIONS/NOTES
MIN
CS = VIL, U/D = VIL or VIH and
INC = 0.42/2.4V @ max tCYC
CS = VCC - 0.3V, U/D and INC = VSS or
VCC - 0.3V
VIN = VSS to VCC
2
VCC = 5V, VIN = VSS, TA = +25°C,
f = 1MHz
Endurance and Data Retention
PARAMETER
MIN
Minimum endurance
100,000
Data retention
100
UNIT
Data changes per bit
per register
Years
LIMITS
TYP
(Note 4)
1
200
10
MAX
3
500
±10
+0.8
UNIT
mA
µA
µA
V
V
pF
VH/RH
VS
TEST POINT
VW/RW
VL/RL
FIGURE 1. TEST CIRCUIT #1
VH/RH
TEST POINT
VWW/RW
FORCE
VL/RL
CURRENT
FIGURE 2. TEST CIRCUIT #2
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
RW
FIGURE 3. CIRCUIT #3 SPICE MACRO
MODEL
Submit Document Feedback
6
FN8177.7
October 7, 2015