English
Language : 

X9116 Datasheet, PDF (6/9 Pages) Xicor Inc. – Digitally Controlled Potentiometer (XDCP)
X9116
DC Electrical Specifications Over recommended operating conditions unless otherwise specified
SYMBOL
PARAMETER
MIN
TYP (NOTE 6)
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tIW
tCYC
tR, tF (Note 7)
tPU (Note 7)
tR VCC (Note 7)
tWR
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time (STORE)
INC to Vw change
INC cycle time
INC input rise and fall time
Power up to wiper stable
VCC Power-up rate
Store cycle
100
100
2.9
1
1
1
10
1
4
15
5
MAX
5
500
5
50
10
UNIT
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
mV/µs
ms
Power Up and Down Requirements
There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer pins
provided that VCC is always more positive than or equal to VH, VL, and VW, i.e., VCC ≥ VH, VL, VW. The VCC ramp rate spec is
always in effect.
A.C. Timing
CS
tCI
INC
tCYC
tIL
tIH
(store)
tIC
tCPH
tID
tDI
90% 90%
10%
tF
tR
U/D
tIW
VW
(Note 8)
MI
NOTES:
6. Typical values are for TA = 25°C and nominal supply voltage.
7. This parameter is not 100% tested.
8. MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position.
6
FN8160.1
September 12, 2005