Operating Specifications Over the recommended operating conditions, unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 19) (Note 5) (Note 19) UNIT
Rpu SDA and SCL Bus Pull-up Resistor Off-chip Maximum is determined by tR and tF
1
kΩ
For Cb = 400pF, max is about 2kΩ~2.5kΩ
For Cb = 40pF, max is about 15kΩ~20kΩ
tSU:A A1 and A0 Setup Time
Before START condition
600
ns
tHD:A A1 and A0 Hold Time
After STOP condition
600
ns
NOTES:
5. Typical values are for TA = +25°C and 3.3V supply voltage.
6. LSB: [V(RW)127 – V(RW)0]/127. V(RW)127 and V(RW)0 are V(RW) for the DCP register set to 7F hex and 00 hex respectively. LSB is the
incremental voltage when changing from one tap to an adjacent tap.
7. ZS error = V(RW)0/LSB.
8. FS error = [V(RW)127 – VCC]/LSB.
9. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 127. i is the DCP register setting.
10. INL = [V(RW)i – (i • LSB) – V(RW)0]/LSB for i = 1 to 127
11. TCV
=
-------M-----a----x----(--V----(---R-----W------)--i--)---–-----M-----i--n----(--V-----(--R-----W------)--i--)------ × ------1---0----6-------
[Max(V(RW)i) + Min(V(RW)i)] ⁄ 2 +165°C
for i = 16 to 127 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
voltage and Min ( ) is the minimum value of the wiper voltage over the temperature
range.
12. MI = |RW127 – RW0|/127. MI is a minimum increment. RW127 and RW0 are the measured resistances for the DCP register set to 7F hex and
00 hex respectively.
13. Roffset = RW0/MI, when measuring between RW and RL.
Roffset = RW127/MI, when measuring between RW and RH.
14. RDNL = (RWi – RWi-1)/MI -1, for i = 16 to 127.
15. RINL = [RWi – (MI • i) – RW0]/MI, for i = 16 to 127.
16.
TCR
=
----[---M-----a----x----(--R-----i--)---–-----M-----i--n----(--R-----i--)--]---- × ------1---0----6-------
[Max(Ri) + Min(Ri)] ⁄ 2 +165°C
for i = 16 to 127, T = -40°C to +125°C. Max() is the maximum value of the resistance and Min () is
the minimum value of the resistance over the temperature range.
17. tWC is the time from a valid STOP condition at the end of a Write sequence of I2C serial interface, to the end of the self-timed internal non-volatile
write cycle.
18. Limits should be considered typical and are not production tested.
19. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by