English
Language : 

ICM7216B_04 Datasheet, PDF (6/18 Pages) Intersil Corporation – 8-Digit, Multi-Function, Frequency Counters/Timers
ICM7216B, ICM7216D
Timing Diagram
INTERNAL
STORE
30ms TO 40ms
INTERNAL
RESET
MEASUREMENT
IN PROGRESS
(INTERNAL ON
7216B)
40ms
60ms
40ms
UPDATE
190ms TO 200ms
FUNCTION:
TIME INTERVAL
PRIMING
MEASUREMENT INTERVAL
UPDATE
INPUT A
PRIMING EDGES
INPUT B
NOTE:
250ns MIN
MEASURED
INTERVAL
(FIRST)
MEASURED
INTERVAL
(LAST)
5. If range is set to 1 event, first and last measured interval will coincide.
FIGURE 1. WAVEFORMS FOR TIME INTERVAL MEASUREMENT (OTHERS ARE SIMILAR, BUT WITHOUT PRIMING PHASE)
Typical Performance Curves
20
fA (MAX) FREQUENCY UNIT COUNTER,
FREQUENCY RATIO MODES
15
10
fA (MAX) fB (MAX) PERIOD,
TIME INTERVAL MODES
5
TA = 25oC
0
3
4
5
6
VDD-VSS (V)
FIGURE 2. fA(MAX), fB(MAX) AS A FUNCTION OF SUPPLY
30
4.5 ≤ VDD ≤ 6V
20
10
25oC
-20oC
85oC
0
0
1
2
3
VDD-VOUT (V)
FIGURE 3. TYPICAL ISEG vs VDD-VOUT