English
Language : 

HSP9501 Datasheet, PDF (6/8 Pages) Intersil Corporation – Programmable Data Buffer
HSP9501
AC Electrical Specifications
VCC = 5.0V ±5%, TA = 0oC to +70oC, Commercial, (Note 5) (Continued)
-32
-25
PARAMETER
SYMBOL
MIN
MAX
MIN
MAX
UNITS
NOTES
MODSEL Setup Time
t MS
10
-
13
-
ns
-
MODSEL Hold Time
t MH
2
-
2
-
ns
-
Clock to Data Out
TOUT
-
16
-
22
ns
-
Output Hold from Clock
TOH
4
-
4
-
ns
-
Rise, Fall Time
TRF
-
6
-
6
ns
Note 4
NOTES:
2. Power supply current is proportional to operating frequency. Typical rating for ICCOP is 5mA/MHz.
3. Output load per test load circuit with switch open and CL = 40pF.
4. Controlled by design or process parameters and not directly tested. Characterized upon initial design and after major process and/or design
changes.
5. AC Testing is performed as follows: Input levels: 0V and 3.0V, timing reference levels = 1.5V, input rise and fall times driven at 1ns/V, output
load CL = 40pF.
Test Load Circuit
DUT
S1
CL (NOTE)
SWITCH S1 OPEN FOR ICCSB AND ICCOP
NOTE: Includes stray and jig capacitance.
±
IOH
1.5V
IOL
EQUIVALENT CIRCUIT
196