English
Language : 

ZL8801 Datasheet, PDF (54/87 Pages) Intersil Corporation – Dual Phase PMBus™ ChargeMode™ Control DC/DC Digital Controller
ZL8801
READ_IOUT (8Ch)
Definition: Returns the combined output current of Phase 0 and Phase 1, i.e., the total output current.
Data Length in Bytes: 2
Data Format: Linear-11
Type: Read Only
Protectable: No
Default Value: N/A
Units: A
Equation: READ_IOUT = Y x 2N
Range: N/A
COMMAND
Format
Bit Position
Access
Function
Default Value
READ_IOUT (8Ch)
Linear-11
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Signed Exponent, N
Signed Mantissa, Y
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
READ_TEMPERATURE_1 (8Dh)
Definition: Returns the temperature reading internal to the device.
Data Length in Bytes: 2
Data Format: Linear-11
Type: Read Only
Protectable: No
Default Value: N/A
Units: °C
Equation: READ_TEMPERATURE_1 = Y x 2N
Range: N/A
COMMAND
READ_INTERNAL_TEMP_1 (8Dh)
Format
Bit Position
Access
Function
Default Value
Linear-11
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Signed Exponent, N
Signed Mantissa, Y
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
READ_TEMPERATURE_2 (8Eh)
Definition: Returns the temperature reading from the external temperature device connected to XTEMP0.
Data Length in Bytes: 2
Data Format: Linear-11
Type: Read Only
Protectable: No
Default Value: N/A
Units: °C
Equation: READ_TEMPERATURE_2 = Y x 2N
Range: N/A
COMMAND
Format
Bit Position
Access
Function
Default Value
READ_EXTERNAL_TEMP_2 (8Eh)
Linear-11
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Signed Exponent, N
Signed Mantissa, Y
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Submit Document Feedback 54
FN8614.3
March 27, 2015