English
Language : 

ZL8800 Datasheet, PDF (53/82 Pages) Intersil Corporation – Dual Channel/Dual Phase PMBus ChargeMode Control DC/DC Digital Controller
ZL8800
READ_VIN (88h)
Definition: Returns the input voltage reading.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: V
Equation: READ_VIN = Y×2N
Range: N/A
COMMAND
Format
Bit Position
Access
Function
Default Value
READ_VIN (88h)
Linear-11
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Signed Exponent, N
Signed Mantissa, Y
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
READ_IIN (89h)
Definition: Returns the input current reading.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: A
Equation: READ_IIN = Y×2N
Range: N/A
COMMAND
READ_IIN (89h)
Format
Linear-11
Bit Position 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Access
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
READ_VOUT (8Bh)
Definition: Returns the output voltage reading.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: Read-only
Protectable: No
Default Value: N/A
Equation: READ_VOUT = READ_VOUT × 2-13
Units: V
COMMAND
Format
Bit Position
Access
Default Value
READ_VOUT (8Bh)
Linear-16 Unsigned
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
53
FN7558.1
October 10, 2013