ZL8802
STATUS_VOUT (7Ah)
Definition: The STATUS_VOUT command returns one data byte with the status of the output voltage.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
Bit Position
Access
Function
Default Value
STATUS_VOUT (7Ah)
Bit Field
7
6
5
4
3
2
1
0
R
R
R
R
R
R
R
R
See Following Table
0
0
0
0
0
0
0
0
BIT NUMBER
7
6
5
4
3:0
STATUS BIT NAME
VOUT_OV_FAULT
VOUT_OV_WARNING
VOUT_UV_WARNING
VOUT_UV_FAULT
Not Used
MEANING
Indicates an output overvoltage fault.
Not used
Not used
Indicates an output undervoltage fault.
Not used
STATUS_IOUT (7Bh)
Definition: The STATUS_IOUT command returns one data byte with the status of the output current.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
Bit Position
Access
Function
Default Value
STATUS_IOUT (7Bh)
Bit Field
7
6
5
4
3
2
1
0
R
R
R
R
R
R
R
R
See Following Table
0
0
0
0
0
0
0
0
BIT NUMBER
7
6
5
4
3:0
STATUS BIT NAME
IOUT_OC_FAULT
Not Used
Not Used
IOUT_UC_FAULT
Not Used
MEANING
An output overcurrent fault has occurred.
Not used
Not used
An output undercurrent fault has occurred.
Not used
Submit Document Feedback 51
FN8760.1
December 11, 2015