A.C. OPERATING CHARACTERISTICS
(VCC = 5V ± 10%, TA = Full Operating Temperature Range unless otherwise stated)
Symbol
Parameter
Min.
Limits
Typ.(4)
tCl
CS to INC setup
100
tlD(5) INC HIGH to U/D change
100
tDI(5) U/D to INC setup
1
tlL
INC LOW period
1
tlH
INC HIGH period
1
tlC
INC inactive to CS inactive
1
tCPHS CS deselect time (STORE)
20
tCPHNS(5 CS deselect time (NO STORE)
1
)
tIW
tCYC
tR, tF(5)
tPU(5)
tR VCC(5)
INC to RW change
INC cycle time
INC input rise and fall time
Power-up to wiper stable
VCC power-up rate
100
4
0.2
Max.
500
500
500
50
Unit
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
µs
V/ms
POWER-UP AND DOWN REQUIREMENTS
The recommended power-up sequence is to apply VCC/VSS first, then the potentiometer voltages. During power-up,
the data sheet parameters for the DCP do not fully apply until 1 millisecond after VCC reaches its final value. The VCC
ramp spec is always in effect. In order to prevent unwanted tap position changes, or an inadvertant store, bring the
CS and INC high before or concurrently with the VCC pin on powerup.
A.C. TIMING
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
tCPHS
90% 90%
10%
tCPHNS
tF
tR
U/D
tIW
RW
MI (3)
5
FN8184.1
September 14, 2005