English
Language : 

X9317_14 Datasheet, PDF (5/13 Pages) Intersil Corporation – Low Noise, Low Power, 100 Taps, Digitally Controlled Potentiometer
X9317
DC Electrical Specifications VCC = 5V ±10%. Boldface limits apply across the operating temperature range, -40°C to +85°C
(Industrial) and 0°C to +70°C (Commercial).
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 13) (Note 9) (Note 13) UNIT
ICC1
VCC Active Current (Increment)
ICC2
VCC Active Current (Store)
(non-volatile write)
ISB
Standby Supply Current
ILI
CS, INC, U/D Input Leakage Current
VIH
CS, INC, U/D Input HIGH Voltage
VIL
CS, INC, U/D Input LOW Voltage
CIN (Note 10) CS, INC, U/D Input Capacitance
CS = VIL, U/D = VIL or VIH and INC = VIL/VIH at
min. tCYC
RL, RH, RW not connected
80
µA
CS = VIH, U/D = VIL or VIH and INC = VIL or VIH.
RL, RH, RW not connected
400
µA
CS  VIH, U/D and INC = VIL
RL, RH, RW not connected
5
µA
VIN = VSS to VCC
-10
+10
µA
VCC x 0.7
VCC + 0.5 V
-0.5
VCC x 0.1 V
VCC = 5V, VIN = VSS, TA = +25°C, f = 1MHz
10
pF
Endurance and Data Retention VCC = 5V ±10%, TA = Full Operating Temperature Range.
PARAMETER
MIN
Minimum Endurance
100,000
Data Retention
100
UNIT
Data changes per bit
Years
Test Circuit
TEST POINT
RW
FORCE
CURRENT
Equivalent Circuit
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
RW
AC Conditions of Test
Input pulse levels
0V to 3V
Input rise and fall times
10ns
Input reference levels
1.5V
AC Electrical Specifications VCC = 5V ±10%. Boldface limits apply across the operating temperature range, -40°C to +85°C
(Industrial) and 0°C to +70°C (Commercial).
SYMBOL
PARAMETER
MIN
(Note 13)
TYP
(Note 9)
MAX
(Note 13)
UNIT
tCl
CS to INC Setup
50
ns
tlD (Note 10)
INC HIGH to U/D Change
100
ns
tDI (Note 10)
U/D to INC Setup
1
µs
tlL
INC LOW Period
960
ns
tlH
INC HIGH Period
960
ns
tlC
INC Inactive to CS Inactive
1
µs
tCPHS
CS Deselect Time (STORE)
10
ms
tCPHNS
CS Deselect Time (NO STORE)
100
ns
(Note 10)
tIW
INC to RW Change
tCYC
INC Cycle Time
1
5
µs
2
µs
Submit Document Feedback
5
FN8183.9
November 4, 2014