X9116_14 Datasheet, PDF (5/9 Pages) Intersil Corporation – Digitally Controlled Potentiometer
X9116
DC Electrical Specifications Over recommended operating conditions unless otherwise specified. Boldface limits apply over the
operating temperature range, -40°C to +85°C or 0°C to +70°C.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 10) (Note 7) (Note 10) UNIT
ICC1
ICC2
ISB
ILI
VIH
VIL
CIN
VCC active current (Increment)
CS = VIL, U/D = VIL or VIH and
INC = 0.4V/2.4V @ max tCYC
VCC active current (Store) (EEPROM Store) CS = VIH, U/D = VIL or VIH and
INC = VIH @ max tWR
Standby supply current
CS = VCC – 0.3V, U/D and INC = VSS or
VCC – 0.3V
CS, INC, U/D input leakage current
VIN = VSS to VCC
CS, INC, U/D input HIGH voltage
2V
CS, INC, U/D input LOW voltage
-0.5
CS, INC, U/D input capacitance
VCC = 5V, VIN = VSS, TA = +25°C,
f = 1MHz
150
µA
400
µA
5
µA
±10
µA
VCC + 0.5 V
0.8
V
10
pF
NOTES:
7. Typical values are for TA = +25°C and nominal supply voltage.
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
100,000
100
UNIT
Data changes per bit
Years
Test Circuit #1
Test Circuit #2
Circuit #3 SPICE Macro Model
VH/RH
VS
Test Point
VW/RW
VL/RL
A.C. Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
VH/RH
Test Point
VWV/RWW
Force
VL/RL
Current
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
RW
5
FN8160.3