English
Language : 

ISL6745A Datasheet, PDF (5/9 Pages) Intersil Corporation – Improved Bridge Controller with Precision Dead Time Control
ISL6745A
Electrical Specifications
Recommended operating conditions unless otherwise noted. Refer to Block Diagram on page 2 and Typical
Application schematic on page 3. 9V < VDD < 16V, RTD = 51.1kΩ, CT = 470pF, TA = -40°C to +105°C, Typical
values are at TA = +25°C; Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise
specified. Temperature limits established by characterization and are not production tested. (Continued)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
SOFT-START
Net Charging Current
45
-
68
µA
SS Clamp Voltage
3.8
4.0
4.2
V
Overcurrent Shutdown Threshold Voltage
(Note 3)
-
3.9
-
V
Overcurrent Discharge Current
12
15
23
µA
Reset Threshold Voltage
0.25
0.27
0.31
V
OUTPUT
High Level Output Voltage (VOH)
Low Level Output Voltage (VOL)
Rise Time
Fall Time
THERMAL PROTECTION
VDD - VOUTA or VOUTB,
IOUT = -100mA
IOUT = 100mA
CGATE = 1nF, VDD = 12V
CGATE = 1nF, VDD = 12V
-
0.5
2.0
V
-
0.5
1.0
V
-
17
60
ns
-
20
60
ns
Thermal Shutdown
(Note 3)
-
145
-
°C
Thermal Shutdown Clear
(Note 3)
-
130
-
°C
Hysteresis, Internal Protection
(Note 3)
-
15
-
°C
NOTES:
3. Limits established by characterization and are not production tested.
5
FN6703.1
September 11, 2008