English
Language : 

ISL22512_15 Datasheet, PDF (5/12 Pages) Intersil Corporation – Low Noise, Low Power, 16 Taps, Push Button Controlled Potentiometer
ISL22512
DC Electrical Specifications
Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 18) (Note 5) (Note 18)
ICC
VCC Active Current
VCC = 5.5V, perform wiper move
150
operation
ICC
VCC Current During Store Operation
VCC = 5.5V, perform non-volatile
2
store operation
ISB
ILkg
VIH
VIL
CIN
(Note 17)
Standby Current
PU, PD Input Leakage Current
PU, PD Input HIGH Voltage
PU, PD input LOW Voltage
PU, PD Input Capacitance
0.6
3
VIN = VSS to VCC
-2
+2
VCC x 0.7
VCC x 0.1
VCC = 3.3V, TA = +25°C, f = 1MHz
10
Rpull_up Pull-Up Resistor for PU and PD
1
(Note 17)
EEPROM SPECIFICATIONS
EEPROM Endurance
1,000,000
EEPROM Retention
Temperature 55°C
50
UNIT
µA
mA
µA
µA
V
V
pF
M
Cycles
Years
AC Electrical Specifications
Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
MIN
(Note 18)
TYP
(Note 5)
MAX
(Note 18)
UNIT
tGAP
Time Between Two Separate Push Button Events
2
ms
tDB
Debounce Time
15
28
ms
tS SLOW Wiper Change on a Slow Mode
100
250
390
ms
tS FAST Wiper Change on a Fast Mode
25
50
78
ms
tstdn
Time to Enter Shutdown Mode (keep PU and PD LOW)
2
s
(Note 17)
tPU
Power-Up to Wiper Stable
500
µs
tR VCC VCC Power-Up Rate
0.2
50
V/ms
NOTES:
5. Typical values are for TA = +25°C and 3.3V supply voltage.
6. LSB: [V(RW)15 – V(RW)0]/15. V(RW)31 and V(RW)0 are voltage on RW pin for the DCP register set to 0F hex and 00 hex respectively. LSB is
the incremental voltage when changing from one tap to an adjacent tap.
7. ZS error = V(RW)0/LSB.
8. FS error = [V(RW)31 – VCC]/LSB.
9. DNL = [V(RW)i – V(RW)i-1]/LSB -1, for i = 1 to 15; i is the DCP register setting.
10. INL = [V(RW)i – i • LSB – V(RW)]/LSB for i = 1 to 15
11. TCV
=
-------M-----a----x------V-------R-----W--------i-----–-----M-----i--n------V-------R-----W--------i--------  ------1---0----6-------for i = 5 to 15 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
MaxVRWi + MinVRWi  2 +165°C voltage and Min ( ) is the minimum value of the wiper voltage over the temperature range.
12. MI = |RW15 – RW0|/15. MI is a minimum increment. RW15 and RW0 are the measured resistances for the DCP register set to 1F hex and 00
hex respectively.
13. Roffset = RW0/MI, when measuring between RW and RL.
Roffset = RW15/MI, when measuring between RW and RH.
14. RDNL = (RWi – RWi-1)/MI, for i = 1 to 15.
15. RINL = [RWi – (MI • i) – RW0]/MI, for i = 1 to 15.
16.
TCR
=
-------M-----a----x------R-----i-----–-----M-----i--n------R-----i--------
MaxRi + MinRi  2

------1---0----6-------
+ 165 °C
for i = 5 to 15, T
minimum value
= -40°C to +125°C. Max( ) is the maximum value
of the resistance over the temperature range.
of
the
resistance
and
Min
(
)
is
the
17. Limits should be considered typical and are not production tested.
18. Parts are 100% tested at +25°C. Temperature limits established by characterization and are not production tested.
5
FN6679.3
October 12, 2015