English
Language : 

HIP6016 Datasheet, PDF (5/14 Pages) Intersil Corporation – Advanced PWM and Dual Linear Power Control
HIP6016
Electrical Specifications Recommended Operating Conditions, Unless Otherwise Noted. Refer to Figures 1, 2 and 3 (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP MAX UNITS
Slew Rate
SR
COMP = 10pF
-
6
-
V/µs
PWM CONTROLLER GATE DRIVER
Upper Drive Source
Upper Drive Sink
Lower Drive Source
Lower Drive Sink
PROTECTION
IUGATE
RUGATE
ILGATE
RLGATE
VCC = 12V, VUGATE (or VGATE2) = 6V
VUGATE-PHASE = 1V
VCC = 12V, VLGATE = 1V
VLGATE = 1V
-
1
-
A
-
1.7 3.5
Ω
-
1
-
A
-
1.4 3.0
Ω
VOUT1 Over-Voltage Trip
FAULT Sourcing Current
OCSET Current Source
Soft-Start Current
Chip Shutdown Soft-Start Threshold
IOVP
IOCSET
ISS
VSEN1 Rising
VFAULT = 10V
VOCSET = 4.5VDC
112 115 118
%
10 14
-
mA
170 200 230
µA
-
11
-
µA
-
-
1.0
V
POWER GOOD
VOUT1 Upper Threshold
VOUT1 Under Voltage
VOUT1 Hysteresis (VSEN1/DACOUT)
PGOOD Voltage Low
VPGOOD
VSEN1 Rising
VSEN1 Rising
Upper/Lower Threshold
IPGOOD = -4mA
108
-
110
%
92
-
94
%
-
2
-
%
-
-
0.5
V
Typical Performance Curves
1000
100
RT PULLUP
TO +12V
10
RT PULLDOWN TO VSS
10
100
SWITCHING FREQUENCY (kHz)
FIGURE 4. RT RESISTANCE vs FREQUENCY
1000
100
CUGATE = CLGATE = CGATE
80
VVCC = 12V
VIN = 5V
60
40
CGATE = 4800pF
CGATE = 3600pF
CGATE = 1500pF
20
CGATE = 660pF
0
100 200
300 400 500 600 700 800
SWITCHING FREQUENCY (kHz)
900 1000
FIGURE 5. BIAS SUPPLY CURRENT vs FREQUENCY