English
Language : 

CD4060BMS Datasheet, PDF (5/9 Pages) Intersil Corporation – CMOS 14 Stage Ripple-Carry Binary Counter/Divider and Oscillator
Specifications CD4060BMS
TABLE 3. ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
LIMITS
PARAMETER
Input Capacitance
SYMBOL
CONDITIONS
CIN
Any Input
NOTES
1, 2
TEMPERATURE MIN
+25oC
-
MAX
7.5
UNITS
pF
NOTES:
1. All voltages referenced to device GND.
2. The parameters listed on Table 3 are controlled via design or process and are not directly tested. These parameters are characterized
on initial design release and upon design changes which would affect these characteristics.
3. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
4. RC Oscillator applications are not recommended at supply voltages below 7V for RX < 50kΩ.
TABLE 4. POST IRRADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS
LIMITS
PARAMETER
Supply Current
N Threshold Voltage
N Threshold Voltage
Delta
P Threshold Voltage
P Threshold Voltage
Delta
Functional
Propagation Delay Time
SYMBOL
CONDITIONS
IDD VDD = 20V, VIN = VDD or GND
VNTH VDD = 10V, ISS = -10µA
∆VTN VDD = 10V, ISS = -10µA
VPTH
∆VTP
VSS = 0V, IDD = 10µA
VSS = 0V, IDD = 10µA
F
TPHL
TPLH
VDD = 18V, VIN = VDD or GND
VDD = 3V, VIN = VDD or GND
VDD = 5V
NOTES: 1. All voltages referenced to device GND.
2. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
NOTES
1, 4
1, 4
1, 4
TEMPERATURE MIN
+25oC
-
+25oC
-2.8
+25oC
-
1, 4
+25oC
0.2
1, 4
+25oC
-
1
1, 2, 3, 4
+25oC
+25oC
VOH >
VDD/2
-
3. See Table 2 for +25oC limit.
4. Read and Record
MAX
25
-0.2
±1
2.8
±1
VOL <
VDD/2
1.35 x
+25oC
Limit
UNITS
µA
V
V
V
V
V
ns
TABLE 5. BURN-IN AND LIFE TEST DELTA PARAMETERS +25OC
PARAMETER
SYMBOL
DELTA LIMIT
Supply Current - MSI-2
Output Current (Sink)
Output Current (Source)
IDD
IOL5
IOH5A
± 1.0µA
± 20% x Pre-Test Reading
± 20% x Pre-Test Reading
CONFORMANCE GROUP
Initial Test (Pre Burn-In)
Interim Test 1 (Post Burn-In)
Interim Test 2 (Post Burn-In)
PDA (Note 1)
Interim Test 3 (Post Burn-In)
PDA (Note 1)
Final Test
Group A
Group B
Subgroup B-5
Subgroup B-6
Group D
TABLE 6. APPLICABLE SUBGROUPS
MIL-STD-883
METHOD
GROUP A SUBGROUPS
100% 5004
1, 7, 9
100% 5004
1, 7, 9
100% 5004
1, 7, 9
100% 5004
1, 7, 9, Deltas
100% 5004
1, 7, 9
100% 5004
1, 7, 9, Deltas
100% 5004
2, 3, 8A, 8B, 10, 11
Sample 5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Sample 5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11, Deltas
Sample 5005
1, 7, 9
Sample 5005
1, 2, 3, 8A, 8B, 9
READ AND RECORD
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
Subgroups 1, 2, 3, 9, 10, 11
Subgroups 1, 2 3
7-953